过氧化氢-茚三酮体系荧光光度法检测食品中的焦磷酸盐
作者:
作者单位:

(1.陕西理工大学 陕西省催化基础与应用重点实验室 陕西汉中 723001;2.陕西理工大学化学与环境科学学院 陕西汉中 723001)

作者简介:

通讯作者:

中图分类号:

基金项目:

陕西省科技厅自然科学基金项目(2018JQ2057);国家级大学生创新创业训练计划项目(202110720022)


Fluorescence Spectrophotometric Method for the Detection of Pyrophosphates in Food Samples with Hydrogen Peroxide-Ninhydrin System
Author:
Affiliation:

(1.Shaanxi Key Laboratory of Catalysis, Shaanxi University of Technology, Hanzhong 723001, Shaanxi;2.School of Chemical & Environmental Sciences, Shaanxi University of Technology, Hanzhong 723001, Shaanxi)

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    摄入过多的焦磷酸盐会对人体健康产生严重影响,因此控制食品中焦磷酸盐的含量十分重要。在酸性介质中,Cu2+能催化过氧化氢-茚三酮体系间的氧化-还原反应而产生较强的荧光。当在该体系中加入少量焦磷酸盐后,Cu2+-H2O2-茚三酮体系的荧光强度显著减弱。基于此,建立一种荧光光度法检测焦磷酸盐含量。考察过氧化氢浓度、茚三酮浓度、Cu2+浓度、反应时间及反应温度等条件对荧光强度的影响。结果表明,最优条件为过氧化氢浓度3.0×10-5 mol/L,茚三酮浓度2.0×10-3 mol/L,Cu2+浓度6.0×10-5 mol/L,反应时间40 min,反应温度30 ℃,在此条件下,减弱的荧光强度与焦磷酸盐浓度在3.0×10-7~8.0×10-6 mol/L范围内的对数值呈良好的线性相关。方法的检出限与相对标准偏差(RSD)分别为3.2×10-8 mol/L,4.9%(C=1.0×10-6 mol/L,n=11)。采用该方法测定虾仁与带鱼样品中焦磷酸盐含量并做加标回收试验,平均回收率在93.00%~97.80%范围,表明该方法可用于实际食品样品中焦磷酸盐含量的准确检测。

    Abstract:

    Pyrophosphate can seriously affect human health. Therefore, it is necessary to control the content of pyrophosphate in food. In the acid medium, copper ion (Cu2+) can effectively catalyze the redox reaction between hydrogen peroxide and ninhydrin, leading to produce a strong fluorescence. When a small amount of pyrophosphate was added into the hydrogen peroxide-ninhydrin system, the above-mentioned fluorescence was obviously reduced. Based on this observation, a fluorescence strategy for the quantitative analysis of pyrophosphate was developed. Several experiment parameters, such as hydrogen peroxide concentration, ninhydrin concentration, Cu2+ concentration, reaction time and reaction temperature were optimized to investigate the effect of these factors on the fluorescence intensity. The result showed that, the optimized experimental conditions was set as follows: 3.0×10-5 mol/L of hydrogen peroxide, 2.0×10-3 mol/L of ninhydrin 6.0×10-5 mol/L of copper ion, 40 min of reaction time and reaction temperature at 30 ℃. Under the conditions,the relative fluorescence intensity displayed a good linear relationship with the logarithm value of pyrophosphate concentration in the range of 3.0×10-7-8.0 ×10-6 mol/L. And the detection limit and the relative standard deviation were 3.2×10-8 mol/L and 4.9% (C=1.0×10-6 mol/L, n=11), respectively. The content of pyrophosphate in the shelled shrimp and hairtail samples were quantified by the proposed method, and the average recoveries were between 93.00% and 97.80%. This result showed that the developed method can be applied in the accurate detection of pyrophosphate content in the practical food samples.

    参考文献
    相似文献
    引证文献
引用本文

熊海涛,徐艺凤,徐承娥.过氧化氢-茚三酮体系荧光光度法检测食品中的焦磷酸盐[J].中国食品学报,2023,23(7):374-381

复制
分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:2022-07-12
  • 最后修改日期:
  • 录用日期:
  • 在线发布日期: 2023-08-17
  • 出版日期:
版权所有 :《中国食品学报》杂志社     京ICP备09084417号-4
地址 :北京市海淀区阜成路北三街8号9层      邮政编码 :100048
电话 :010-65223596 65265375      电子邮箱 :chinaspxb@vip.163.com
技术支持:北京勤云科技发展有限公司

漂浮通知