    摘要:

    建立手性色谱法测定L-5-甲基四氢叶酸钙(L-5-MTHF-Ca)的分析方法,通过方法学验证评价方法的可行性。使用高效液相色谱系统,色谱柱为CHIRALPAK HSA手性色谱柱(4 mm×150 mm,5 μm),以磷酸盐缓冲溶液∶乙腈(体积比90 ∶ 10)为流动相,流速0.6 mL/min,进样量5 μL,柱温30 ℃,检测波长280 nm。方法学验证结果表明,此方法可很好地分离L-5-MTHF-Ca,分离度达到3.24, 并且在0.016~0.100 mg/mL质量浓度范围线性关系良好,相关系数为0.9997,检出限为3.11 μg/mL,定量限为4.98 μg/mL,精密度0.38%,加标平均回收率103.71%,系统适用性良好,然而,L-5-MTHF-Ca会随时间缓慢降解,需尽快进样分析。方法操作简便,结果准确,可用于各种食品、保健品中L-5-MTHF-Ca含量的测定。

    Abstract:

    A chiral chromatographic method for the determination of calcium L-5-methyltetrahydrofolate (L-5-MTHF-Ca) was established, and the feasibility of the method was evaluated by methodology validation. Methods high performance liquid chromatography is used. The chromatographic column is CHIRALPAK HSA chiral column (4 mm×150 mm, 5 μm). The mobile phase is phosphate buffer solution ∶ acetonitrile (90 ∶ 10, V ∶ V). The flow rate is 0.6 mL/min. The injection volume is 5 μL. The column temperature is 30 ℃ and the detection wavelength is 280 nm. The results shows that the method could separate L-5-MTHF-Ca well, the resolution is 3.24, and the linear relationship is good in the concentration range of 0.016~0.100 mg/mL, the correlation coefficient is 0.9997, the detection limit and quantitation limit are 3.11 μg/mL and 4.98 μg/mL respectively, the precision is 0.38%, and the average recovery is 103.71%. System suitability test results are good, but L-5-MTHF-Ca will slowly degrade over time, so sample analysis as soon as possible. The method is simple, accurate and can be used for the determination of L-5-MTHF-Ca in various foods and health products.

    参考文献
    相似文献
    引证文献
引用本文

倪兴刚,邓泽元,李静,揭琴丰,李露敏,王杉.手性色谱法测定L-5-甲基四氢叶酸钙含量[J].中国食品学报,2022,22(9):270-275

复制
分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:2021-09-11
  • 最后修改日期:
  • 录用日期:
  • 在线发布日期: 2022-10-26
  • 出版日期:
文章二维码
版权所有 :《中国食品学报》杂志社     京ICP备09084417号-4
地址 :北京市海淀区阜成路北三街8号9层      邮政编码 :100048
电话 :010-65223596 65265375      电子邮箱 :chinaspxb@vip.163.com
技术支持:北京勤云科技发展有限公司

漂浮通知


×
《中国食品学报》杂志社招聘编辑